5 Slot ATCA System with Pigeon Point Shelf Management and Front Removable Fan Tray
 |
SYSTEM |
| - |
Fully assembled and tested chassis |
| - |
19" Rack mountable |
| - |
5 Slot Full Mesh backplane with interface for two Schroff Shelf Managers with bused IPMB |
| |
- |
110V AC input |
| |
- |
Designed for easy access to top board via removable top cover and cover plate (perfect for board test and debug) |
| |
- |
Front removable fan tray |
| |
- |
Cooling via two 290 CFM fans; cooling for up to 200 Watts per board (alternative lower CFM fan versions available upon request) |
| |
- |
Mounting provisons for five 8Ux280mm AdvancedTCA boards, five 8Ux70mm rear transition modules, and two Schroff 4Ux6HP shelf managers on standard DC unit; AC unit does not have RTM's |
| |
- |
Shielded design |
| |
- |
Designed to meet NEBS requirements for cooling, noise, and shielding |
| |
- |
New deployment configuration with front removable fan tray |
| |
|
|
| |
BACKPLANE |
| |
- |
Five slot Full Mesh backplane with slots numbered from bottom to top (horizontal mounting in card cage) |
| |
- |
Fabric: wired as a Full Mesh with a full eight pair channel which connects each AdvancedTCA board directly to each of the other AdvancedTCA boards in the backplane |
| |
- |
Base Interface: wired as a dual star, slots 1 and 2 are the base interface hub slots. The base interface routes four pair base channels to all slots |
| |
- |
IPMB_A and IPMB_B connections are wired as a bus |
| |
- |
Update Channel: routes a full ten pair channel from slot 1 to slot 2 and from slot 3 to slot 4 |
| |
- |
Metallic Test Bus: two pairs of the metallic test bus signals are routed to all slots |
| |
- |
Hardware Addressing: each AdvancedTCA slot will be assigned a unique hardware address. The addresses for slots 1-5 will be 41h through 45h |
| |
|
|
| |
SHELF MANAGER |
| |
- |
Schroff ACB II Shelf Manager BPL000763 |
| |
- |
4U high 6HP wide 280mm deep Schroff Shelf Manager |
| |
- |
Based on Pigeon Point Sentry ShMM-300 Shelf Manager |
| |
- |
Bused IPMB interface |
| |
- |
Includes front panel with AdvancedTCA handle and gasketing |
| |
|
|
| |
Ordering Information
| Part Number |
Description |
| SYS001916 |
5 Slot Full Mesh Dual Inputs integrated System, Front Removable Fan Tray |
| BPL000763 |
Schroff Shelf Manager 4U 6HP for 5 Slot Chassis |
| CBL000001 |
Cable To Connect PC To Shelf Manager (RJ45 to DB9) |
| FPL000765 |
Filler Panel For Empty 4U Shelf Manager Slots |
| 21591098 |
Air Baffle/Filler Panel For 8U 280mm Front Board Slot |
| 21591099 |
Air Baffle/Filler Panel For 8U 79mm Rear Board Slot |
|